Temperature transmitter, with diagnostic output, DC PNP/NPN, Redundant sensor elements, with backup function, Communication interface: IO-Link 1.1, (COM1 slave, 4.8 kBaud), Analogue output 4...20 mA, (NAMUR NE43, NE89), Diagnostic output for drift and fault monitoring
Application: liquids and gases
Process connection: G 1 A / Aseptoflex Vario
Operating voltage: 18...32
Electrical design: DC PNP/NPN

  Customer benefits
Exact measured values enable a consumption-oriented compressed air supply. With the information about the current consumption the system could be optimised: Consumption was halved using a simple low-cost electrical valve and a switch-off system depending on requirement. This optimisation was only possible after the compressed air consumption was determined. The additional leakage monitoring detects very small leaks, which can then be removed quickly. This reduces expensive compressed air losses.
Compressed air meter, DC PNP, Communication interface: IO-Link 1.1 (COM2 slave, 38.4 kBaud), Function programmable, 2 outputs, OUT1: flow monitoring (binary), quantity meter (pulse), preset counter (binary), OUT2: flow or temperature monitoring (analogue or binary), flow monitoring, Display range, 0.0...90 Nm³/h, Measuring range, 0.2...75 Nm³/h, Temperature monitoring, Display range, -10...100 °C, Connector, 4-digit alphanumeric display
Application: Compressed air, Air quality(DIN 8573-1): , Class 141 (measuring error: see below, value A), Class 344 (measuring error: see below, value B)
Operating voltage: 18...30 V DC
Electrical design: DC PNP
 
 
 
 
Compressed air meter, DC PNP, Communication interface: IO-Link 1.1 (COM2 slave, 38.4 kBaud), Function programmable, 2 outputs, OUT1: flow monitoring (binary), quantity meter (pulse), preset counter (binary), OUT2: flow or temperature monitoring (analogue or binary), flow monitoring, Display range, 0...840 Nm³/h, Measuring range, 2.3 (3)...700 Nm³/h , Temperature monitoring, Display range, -10...100 °C, Connector, 4-digit alphanumeric display
Application: Compressed air, Air quality(DIN 8573-1): , Class 141 (measuring error: see below, value A), Class 344 (measuring error: see below, value B)
Operating voltage: 18...30 V DC

Evaluation unit for temperature sensors, DC PNP/NPN, Communication interface: IO-Link 1.0, (COM2 slave, 38.4 kBaud), 4-digit alphanumeric display, Switching output, analogue output 4...20 mA or 0...10 V, 4-digit alphanumeric display
Process connection: G½ A
Operating voltage: 18...32 V DC
Electrical design: DC PNP/NPN
Output function: 1 x normally open / closed programmable + 1 x analogue (4...20 mA / 0...10 V, scalable)
Current rating: 250 mA
Measuring range: -40...300 °C / -40...572 °F
Connection: M12 connector
Housing materials: stainless steel (304S15) EPDM

Electronic pressure sensor, with analogue display, DC PNP/NPN, Suitable for all standard CIP and SIP processes, Analogue display 0...350° rotatable, Resolution 0.25%, Pointer not visible when unit disconnected, Connector, analogue display, 4-digit alphanumeric display, 2 outputs, OUT1 = switching output, OUT2 = analogue output, 4-digit alphanumeric display
Application: Type of pressure: relative pressure , Hygienic systems, viscous media and liquids with suspended particles, Liquids and gases
Process connection: G 1 A / Aseptoflex Vario
Operating voltage: 18...32 V DC
Electrical design: DC PNP/NPN
Output function: 1 x normally open / closed pr
 
               