Thứ Tư, 26 tháng 11, 2014

Power tranf: DC: RXTUG 22H; U1=(24-250VDC); U2=(±12/18/24VDC)

Arc protection relay CM-KRN 24V DC
1SVR450089R1000
V18345-1017421001
Power tranf:  DC: RXTUG 22H; U1=(24-250VDC); U2=(±12/18/24VDC)
Code: 1MRK000 592-A.
RXTTE4; U=110VAC, 1A
Code: 1MRK002 108-BA.
RXHL421-1MRK001975-AB
1MRK001975-AB
(RXHL421; U=110VAC, 1A
Code: replaced for 1MRK000 322-FG)
1 CGA Continuous Gas Analyzer
1 AO2000 System
1 2 System housings
2 System bus cable 1 m
3 System-plug with T-connector
1 2 System bus plug with Terminator
1 Supply voltage 230 V AC
1 1 Manual EN
1 Wall-Mounted Housing AO2040
1 Wall-mounted Housing
1 Protection Class IP20
1 Standard Power Supply 100…240 V, 50…60 Hz
1 for Limas11
1 with display and control unit
1 Dust protection cap for electronic
1 AO Electronics
1 Digital I/O Module (4 x DO / 4 x DI)
1 Status / Ext. Calibration
1 Analog Output Module (4 x AO)
1 Analog Output Module (2 x AO)
1 User Interface Language: German/English
1 Pneumatic Module
1 with O2 sensor in existing analyzer module     O2: 0….25 Vol.%
1 with fine filter in meas. gas path 1
1 Limas11 UV -Process Photometer
1 3 Measurement Components
1 3 Calibration cell
1 Standard meas. cell
1 EDL (low power)
1 1. Measuring Component       NO
1 Measuring Range 1, MC 1     0….1500 mg/m³
1 Accompanying gases 1         CO 1000mg/m³;CO2 10vol%;O2     10vol%;N2 79.83vol%
1 2. Measuring Component       SO2
1 Measuring Range 1, MC 2      0….1000 mg/m³
1 3. Measuring Component        NO2
1 Measuring Range 1, MC 3       0…..500 mg/m³
1 Int. CS correction of 2nd MC by 3rd MC             Q23
1 Group B gases
1 Wall-Mounted Housing AO2040
1 Wall-mounted Housing
1 Protection Class IP20
1 Standard Power Supply 100…240 V, 50…60 Hz
1 for Uras26
1 Ready for 1 Analyzer
1 Uras26-Infrared Photometer
1 2 Measurement Components
1 1. Measuring Component         CO2
1 Measuring Range 1, MC 1        0…..20 vol%
1 Measuring Range 2, MC 1        0…..20 vol%
1 2. Measuring Component         CO
1 Measuring Range 1, MC 2        0….500 mg/m³
1 Measuring Range 2, MC2         0….500 mg/m³
1 Accompanying gas                  O2: 5 vol%
1 Accompanying gas                  NO: 1000 mg/m³
1 Accompanying gas                  SO2: 1000 mg/m³
1 Accompanying gas                  N2: 84.87 vol%
1 Pressure Sensor in gas path 1
1 with 2 Calibration Cells
1 with reduced temperature influence
1 1st beam for …                        CO2 (1)
1 2nd beam for …                       CO (1)