ASHCROFT Vietnam, Cambodia, China, |
Model DM61 Digital Panel Meter | •
0.10% Span Accuracy • Six Digit Display • Field Selectable Outputs: 0-20 4-20 mA, +/-10 Vdc (0-5, 1-5, 0-10 Vdc), Modbus PV (slave) • User-Programmable Buttons/Display • 12 or 24 V Power Supply • Optional USB, RS-232 and RS-485 Communication Adapters • Optional Relays and Digital I/O Expansion Modules |
ASHCROFT Vietnam, Cambodia, China, |
Type K2 Thin Film Pressure Transducer with Conditioned Millivolt Output | 0.5% and 1.0% accuracy Vac - 20,000 psi pressure range Superior long-term stability and repeatability Stainless Steel NEMA 4X enclosure Conditioned millivolt output Wide range of pressure and electrical connections available |
ASHCROFT Vietnam, Cambodia, China, |
Type K8 Thin Film Pressure Transducer with Unconditioned MilliVolt Output | 0.5% and 1.0% accuracy 45 - 20,000 psi pressure ranges Superior long-term stability and repeatability Wide range of pressure and electrical connections available Miniature size and light weight Millivolt output |
ASHCROFT Vietnam, Cambodia, China, |
Type KM15 Rugged, Compact Transducer for the High Volume
OEM |
Compact Size RoHS Compliant All welded sensor -40/120°C operating temp. Rugged SS construction IP 67 ingress protection rating Ranges through 7500 psi |
ASHCROFT Vietnam, Cambodia, China, |
Type KS Thin Film Pressure Transducer/Transmitter for Sanitary Applications | 316L Stainless Steel electropolished (1-1/2" - 2") Tri-Clamp® style diaphragm Vac - 1,000 psi pressure range Stainless Steel NEMA 4X enclosure Superior long-term stability and repeatability Current/voltage/millivolt output Wide range of electrical connections available All-welded construction |
ASHCROFT Vietnam, Cambodia, China, |
Type KX Flush Mount Thin Film Pressure Transducer/Transmitter
for Pulp and Paper Applications |
Available with PMC adapter (shown) Flush-mounted integral 316 Stainless Steel diaphragm Stainless Steel NEMA 4X enclosure Current/voltage output |
ASHCROFT Vietnam, Cambodia, China, |
Type T2 High Performance Pressure Transducer for General
Industrial Applications |
0.25% accuracy class Ranges 30 psi through 20,000 psi Broad temperature capability All-welded pressure construction Proven polysilicon thin film sensor Precision ASIC based electronics High EMI/RFI immunity rating Highly configurable Voltage and current outputs Choice of electrical connections |
ASHCROFT Vietnam, Cambodia, China, |
Type CXLdp Differential Pressure Transmitter |
Rugged ABS enclosure capable of DIN rail or surface
mounting LED power status indicator to assist in trouble shooting, correct wiring or quickly locating the instrument on a duct Detachable Euro style terminal block reduces wiring errors and field wiring time 20 standard pressure ranges all capable of withstanding 15 psi without damage or calibration change Digitally compensated. NIST traceable 0.4% F.S. and 0.8% F.S. accuracy models |
ASHCROFT Vietnam, Cambodia, China, |
Type DXLdp Low Pressure Differential Transducer/Transmitter | The exclusive patented Ashcroft® SpoolCal® actuator provides in-place system calibration without disturbing process tubes (available on pressure ranges up to 50IW maximum.) Front access test jacks provide on-line signal reference without removing wiring LED range status indicators for instant troubleshooting information DIN Rail Mount - dramatically reduces installation and calibration costs 2:1 range turndown options CE standard with all outputs On-board voltage regulation allows use of lower cost, unregulated power supply |
ASHCROFT Vietnam, Cambodia, China, |
CXLdp - Differential Pressure Transmitter - HVAC, comfort control | Static or velocity pressure measurement for ducts, building pressure, filter efficiency, VAV boxes, room pressurization 0.1 to 25 in.W.C. unidirectional, ±0.1 to ±15 in.W.C. bidirectional differential pressure ±0.4%, ±0.8% Span Glass, silicon, aluminum, Valox™, silicone, brass 4-20 mA, 0-10 Vdc, 0-5 Vdc |
ASHCROFT Vietnam, Cambodia, China, |
DXLdp - Differential Pressure Transmitter - Pharmaceutical,
critical room control, featuring SpoolCal™ |
Bio-pharm, bio-tech, room pressurization and control, velocity pressures - applications requiring high stability measurements. 0.1 to 50 in.W.C. unidirectional, ±0.05 to ±25 in.W.C. bidirectional differential pressure; 2:1 turndown option ±0.25%, ±0.5%, ±1.0% Span Glass, silicon, aluminum, Valox™, silicone, nickel plated brass 4-20 mA, 0-5 Vdc, 0-10 Vdc, 1-5 Vdc, 1-6 Vdc, 0.5-4.5 Vdc Ratiometric |
ASHCROFT Vietnam, Cambodia, China, |
GC30 Ultra-Compact Differential Pressure Sensor - with 3-in-1 Digital Pressure Gauge, Transducer and Switch | Filter monitoring, clean room pressure differential, combustion intake flow, fan speed control airflow, alarm & control digital gauge 0.25" to 25" W.C. Differential, ±0.25" to ±25" W. C. Compound Differential ±1.5% F.S. Aluminum, ABS ceramic, silicon and silicone (suitable for clean dry air/gas compatible with materials stated) 1-5 Vdc (Analog), 30 Vdc/80 mA(Switch), NPN or PNP Type |
ASHCROFT Vietnam, Cambodia, China, |
GC52 - Rangeable wet/wet Differential Pressure Transmitter - with integral digital display | Pressurized and non-pressurized tank levels, flow measurement (liquid or gas), fume hoods 4 to 400 in.W.C. unidirectional, ±4 to ±200 in.W.C. bidirectional differential pressure ±0.5% Span 316 Stainless Steel, viton, alumina ceramic 4-20 mA |
ASHCROFT Vietnam, Cambodia, China, |
IXLdp - Low Differential Pressure Transmitter - Industrial
rugged type, NEMA 4X housing with optional intrinsically safe approval |
HVAC - critical environment control, fume hood control, lab/clean room pressurization, laminar flow, furnace/stack draft, leak detection, pollution monitoring, fan tracking, filter monitoring and velocity measurements 0.1 to 200 in.W.C. unidirectional, ±0.05 to ±100 in.W.C. bidirectional differential pressure ±0.25%, ±0.5% Span Glass, silicon, aluminum, silicone, Stainless Steel 4-20 mA, 0-5 Vdc, 1-5 Vdc, 1-6 Vdc, ±2.5 Vdc, ±5.0 Vdc |